संरचित पाठ: Difference between revisions
m (removed Category:Vigyan Ready using HotCat) |
No edit summary |
||
(2 intermediate revisions by 2 users not shown) | |||
Line 109: | Line 109: | ||
END_FUNCTION_BLOCK | END_FUNCTION_BLOCK | ||
</syntaxhighlight> | </syntaxhighlight> | ||
==संदर्भ== | |||
{{reflist}} | |||
<!--Categories--> | |||
[[Category:Articles with hatnote templates targeting a nonexistent page]] | [[Category:Articles with hatnote templates targeting a nonexistent page]] | ||
[[Category:CS1 errors]] | [[Category:CS1 errors]] | ||
[[Category:Created On 02/05/2023]] | [[Category:Created On 02/05/2023]] | ||
[[Category:Lua-based templates]] | |||
[[Category:Machine Translated Page]] | [[Category:Machine Translated Page]] | ||
[[Category:Pages with script errors]] | [[Category:Pages with script errors]] | ||
Line 120: | Line 137: | ||
[[Category:Templates that add a tracking category]] | [[Category:Templates that add a tracking category]] | ||
[[Category:Templates that generate short descriptions]] | [[Category:Templates that generate short descriptions]] | ||
[[Category:Templates using TemplateData]] | |||
[[Category:आईईसी मानकों]] | |||
[[Category:प्रोग्राम करने योग्य तर्क नियंत्रक]] | |||
[[Category:प्रोग्रामिंग भाषा]] | |||
Latest revision as of 18:03, 18 May 2023
संरचित पाठ, जिसे एसटी या एसटीएक्स के रूप में संक्षिप्त किया गया है, IEC 61131-3 मानक द्वारा समर्थित पाँच भाषाओं में से एक है, जिसे निर्देशयोग्य तर्क नियंत्रक (PLCs) के लिए अभिकल्पित किया गया है। [1][2] यह एक उच्च स्तरीय भाषा है जो खण्ड (प्रोग्रामिंग) है और वाक्यात्मक रूप से पास्कल (प्रोग्रामिंग भाषा) से मिलती जुलती है, जिस पर यह आधारित है।[3] सभी भाषाएँ IEC61131 सामान्य तत्वों को साझा करती हैं। चर और फलन निर्देश सामान्य तत्वों द्वारा परिभाषित किए जाते हैं इसलिए IEC 61131-3 मानक के भीतर विभिन्न भाषाओं का उपयोग एक ही कार्यक्रम में किया जा सकता है।
जटिल कथन और स्थिर निर्देश समर्थित हैं:
- पुनरावृति आवर्ती (REPEAT-UNTIL; WHILE-DO)
- सशर्त निष्पादन (IF-THEN-ELSE; CASE)[3]
- कार्य (एसक्यूआरटी (), एसआईएन ())
प्रतिरूप क्रमादेश
(* simple state machine *)
TxtState := STATES[StateMachine];
CASE StateMachine OF
1: ClosingValve();
StateMachine := 2;
2: OpeningValve();
ELSE
BadCase();
END_CASE;
कुछ अन्य प्रोग्रामिंग भाषाओं के विपरीत, सीएएसई वर्णन के लिए कोई फॉलथ्रू नहीं है: पहली मिलान स्थिति दर्ज की जाती है, और इसके वर्णन चलाने के बाद, अन्य स्तिथियों की जाँच किए बिना सीएएसई खण्ड छोड़ दिया जाता है।
अतिरिक्त एसटी प्रोग्रामिंग उदाहरण
// PLC configuration
CONFIGURATION DefaultCfg
VAR_GLOBAL
b_Start_Stop : BOOL; // Global variable to represent a boolean.
b_ON_OFF : BOOL; // Global variable to represent a boolean.
Start_Stop AT %IX0.0:BOOL; // Digital input of the PLC (Address 0.0)
ON_OFF AT %QX0.0:BOOL; // Digital output of the PLC (Address 0.0). (Coil)
END_VAR
// Schedule the main program to be executed every 20 ms
TASK Tick(INTERVAL := t#20ms);
PROGRAM Main WITH Tick : Monitor_Start_Stop;
END_CONFIGURATION
PROGRAM Monitor_Start_Stop // Actual Program
VAR_EXTERNAL
Start_Stop : BOOL;
ON_OFF : BOOL;
END_VAR
VAR // Temporary variables for logic handling
ONS_Trig : BOOL;
Rising_ONS : BOOL;
END_VAR
// Start of Logic
// Catch the Rising Edge One Shot of the Start_Stop input
ONS_Trig := Start_Stop AND NOT Rising_ONS;
// Main Logic for Run_Contact -- Toggle ON / Toggle OFF ---
ON_OFF := (ONS_Trig AND NOT ON_OFF) OR (ON_OFF AND NOT ONS_Trig);
// Rising One Shot logic
Rising_ONS := Start_Stop;
END_PROGRAM
फलन खण्ड उदाहरण
//=======================================================================
// Function Block Timed Counter : Incremental count of the timed interval
//=======================================================================
FUNCTION_BLOCK FB_Timed_Counter
VAR_INPUT
Execute : BOOL := FALSE; // Trigger signal to begin Timed Counting
Time_Increment : REAL := 1.25; // Enter Cycle Time (Seconds) between counts
Count_Cycles : INT := 20; // Number of Desired Count Cycles
END_VAR
VAR_OUTPUT
Timer_Done_Bit : BOOL := FALSE; // One Shot Bit indicating Timer Cycle Done
Count_Complete : BOOL := FALSE; // Output Bit indicating the Count is complete
Current_Count : INT := 0; // Accumulating Value of Counter
END_VAR
VAR
CycleTimer : TON; // Timer FB from Command Library
CycleCounter : CTU; // Counter FB from Command Library
TimerPreset : TIME; // Converted Time_Increment in Seconds to MS
END_VAR
// Start of Function Block programming
TimerPreset := REAL_TO_TIME(in := Time_Increment) * 1000;
CycleTimer(
in := Execute AND NOT CycleTimer.Q,
pt := TimerPreset);
Timer_Done_Bit := CycleTimer.Q;
CycleCounter(
cu := CycleTimer.Q,
r := NOT Execute,
pv := Count_Cycles);
Current_Count := CycleCounter.cv;
Count_Complete := CycleCounter.q;
END_FUNCTION_BLOCK
संदर्भ