रॉन्टजेन (यूनिट): Difference between revisions

From Vigyanwiki
No edit summary
No edit summary
 
(4 intermediate revisions by 4 users not shown)
Line 1: Line 1:
{{Short description|Measurement of radiation exposure}}
{{Short description|Measurement of radiation exposure}}
{{Distinguish|रेंटजेन समकक्ष व्यक्ति|रेंटजेन समकक्ष भौतिकी}}
{{Infobox unit
{{Infobox unit
| name = Roentgen
| name = रॉन्टगन
| image = [[File:Dosimeter ablesung.jpg|200px]]
| image = [[File:Dosimeter ablesung.jpg|200px]]
| caption = Display of [[quartz fiber dosimeter]], in units of roentgen.<ref name="Frame">{{cite web
| caption = Display of [[quartz fiber dosimeter]], in units of roentgen.<ref name="Frame">{{cite web
Line 13: Line 12:
   | url = https://www.orau.org/health-physics-museum/collection/dosimeters/pocket-chambers/index.html
   | url = https://www.orau.org/health-physics-museum/collection/dosimeters/pocket-chambers/index.html
   | access-date = 2021-10-07}}</ref>
   | access-date = 2021-10-07}}</ref>
| standard = Legacy unit
| standard = लीगेसी यूनिट
| quantity = [[Radiation exposure|Exposure to ionizing radiation]]
| quantity = [[विकिरण जोखिम|आयनीकरण विकिरण के संपर्क में]]
| symbol = R
| symbol = R
| dimension =
| dimension =
| namedafter = [[Wilhelm Röntgen]]
| namedafter = [[विल्हेम रॉन्टगन]]
| units1 = [[SI base unit]]s
| units1 = [[एसआई आधार इकाई]]
| inunits1 = {{val|2.58|e=-4}} [[ampere|A]]⋅[[second|s]]/[[kilogram|kg]]
| inunits1 = {{val|2.58|e=-4}} [[एम्पीयर|]]⋅[[सेकंड|एस]]/[[किलोग्राम|किग्रा]]
}}
}}


रेंटजेन या रेंटजेन ({{IPAc-en|ˈ|r|ɜː|n|t|g|ə|n}}; प्रतीक आर) [[एक्स-रे]] और [[गामा किरण]]ों के [[विकिरण]] खतरे के लिए माप की विरासत इकाई है, और इसे उस हवा के [[द्रव्यमान]] से विभाजित हवा की निर्दिष्ट मात्रा में इस तरह के विकिरण द्वारा मुक्त विद्युत आवेश के रूप में परिभाषित किया गया है ([[statcoulomb|स्टैट कूलम्ब]] प्रति किलोग्राम) .
'''रेंटजेन''' या रॉन्टगन ({{IPAc-en|ˈ|r|ɜː|n|t|g|ə|n}}; प्रतीक आर) मुख्यतः [[एक्स-रे]] और [[गामा किरण|गामा किरणों]] के [[विकिरण]] से होने वाले खतरों के लिए मापन की मुख्य इकाई है, और इसे उस हवा के [[द्रव्यमान]] ([[statcoulomb|स्टैट कूलम्ब]] प्रति किलोग्राम) से विभाजित हवा की निर्दिष्ट मात्रा में इस प्रकार के विकिरण द्वारा मुक्त विद्युत आवेश के रूप में परिभाषित किया गया है।


1928 में, इसे [[विकिरण सुरक्षा]] के लिए परिभाषित किए जाने वाले आयनीकरण विकिरण के लिए पहली अंतर्राष्ट्रीय माप मात्रा के रूप में अपनाया गया था, क्योंकि तब यह [[आयन कक्ष]] का उपयोग करके वायु आयनीकरण को मापने की सबसे आसानी से दोहराई जाने वाली विधि थी।<ref name="princetonguide">{{cite web |url=http://web.princeton.edu/sites/ehs/radsafeguide/rsg_app_e.htm |title=Princeton Radiation Safety Guide, Appendix E: Roentgens, RADs, REMs, and other Units |access-date=10 May 2012 |url-status=dead |archive-url=https://web.archive.org/web/20150222005351/http://web.princeton.edu/sites/ehs/radsafeguide/rsg_app_e.htm |archive-date=2015-02-22}}</ref> इसका नाम [[जर्मनी]] के भौतिक विज्ञानी विल्हेम रॉन्टगन के नाम पर रखा गया है, जिन्होंने एक्स-रे की खोज की थी और इस खोज के लिए उन्हें भौतिकी का पहला नोबेल पुरस्कार दिया गया था।
1928 में, इसे [[विकिरण सुरक्षा]] के लिए परिभाषित किए जाने वाले आयनीकरण विकिरण के लिए प्रथम अंतर्राष्ट्रीय माप मात्रा के रूप में अपनाया गया था, क्योंकि इस प्रकार तब यह [[आयन कक्ष]] का उपयोग करके वायु आयनीकरण को मापने की सबसे सरलता से दोहराई जाने वाली विधि थी।<ref name="princetonguide">{{cite web |url=http://web.princeton.edu/sites/ehs/radsafeguide/rsg_app_e.htm |title=Princeton Radiation Safety Guide, Appendix E: Roentgens, RADs, REMs, and other Units |access-date=10 May 2012 |url-status=dead |archive-url=https://web.archive.org/web/20150222005351/http://web.princeton.edu/sites/ehs/radsafeguide/rsg_app_e.htm |archive-date=2015-02-22}}</ref> इसका नाम [[जर्मनी]] के भौतिक विज्ञानी विल्हेम रॉन्टगन के नाम पर रखा गया है, जिन्होंने एक्स-रे की खोज की थी और इस खोज के लिए उन्हें भौतिकी का पहला नोबेल पुरस्कार दिया गया था।


चूंकि, चूंकि यह विकिरण मापन के मानकीकरण में बड़ा कदम था, रेंटजेन का हानि यह है कि यह केवल वायु आयनीकरण का उपाय है, और अन्य सामग्रियों में विकिरण अवशोषण का प्रत्यक्ष उपाय नहीं है, जैसे कि मानव ऊतक के विभिन्न रूप। उदाहरण के लिए, रॉन्टजेन जमा {{convert|0.00877|Gy|rad|abbr=off|lk=on}} शुष्क हवा में [[अवशोषित खुराक|अवशोषित अंश]], या {{convert|0.0096|Gy|rad|abbr=on}} कोमल ऊतक में।<ref name="princetonguide" />एक्स-रे का रॉन्टजेन कहीं से भी जमा हो सकता है {{convert|0.01|to|0.04|Gy|rad|abbr=on}} बीम ऊर्जा के आधार पर हड्डी में।<ref>{{cite web|last=Sprawls|first=Perry|title=विकिरण मात्रा और इकाइयां|url=http://www.sprawls.org/ppmi2/RADQU/3RADQU08.gif|work=The Physical Principles of Medical Imaging, 2nd Ed|access-date=10 May 2012}}</ref>
चूंकि यह विकिरण मापन के मानकीकरण में बड़ी पहल थी, रेंटजेन का हानि यह है कि यह केवल वायु आयनीकरण का उपाय है, और इस प्रकार अन्य पदार्थों में विकिरण अवशोषण का प्रत्यक्ष उपाय नहीं है, जैसे कि मानव ऊतक के विभिन्न रूप में उदाहरण के लिए, रॉन्टजेन एकत्रीकरण में {{convert|0.00877|Gy|rad|abbr=off|lk=on}} शुष्क हवा में [[अवशोषित खुराक|अवशोषित अंश]], या {{convert|0.0096|Gy|rad|abbr=on}} कोमल ऊतक में इसका उपयोग किया गया हैं।<ref name="princetonguide" /> इसी प्रकार एक्स-रे का {{convert|0.01|to|0.04|Gy|rad|abbr=on}} बीम ऊर्जा के आधार पर हड्डी में रॉन्टजेन का कहीं से भी एकत्रीकरण हो सकता है।<ref>{{cite web|last=Sprawls|first=Perry|title=विकिरण मात्रा और इकाइयां|url=http://www.sprawls.org/ppmi2/RADQU/3RADQU08.gif|work=The Physical Principles of Medical Imaging, 2nd Ed|access-date=10 May 2012}}</ref> जैसा कि विकिरण [[मात्रामापी]] का विज्ञान विकसित हुआ, यह प्राप्त किया गया कि आयनीकरण प्रभाव, और इसलिए ऊतक क्षति, अवशोषित ऊर्जा से न कि केवल विकिरण खतरे से जुड़ी थी। इसके परिणामस्वरूप विकिरण सुरक्षा के लिए नई रेडियोमेट्रिक इकाइयां परिभाषित की गईं थी, जिन्होंने इसे ध्यान में रखा था। इस प्रकार 1953 में विकरण यूनिट्स एंड मेजरमेंट्स (आईसीआरयू) पर अंतर्राष्ट्रीय आयोग ने नई विकिरण मात्रा अवशोषित अंश के माप की इकाई के रूप में 100 ईआरजी/ग्राम के समान रेड की परिकाष्ठा की थी। इस प्रकार रेड को इकाइयों की सुसंगत सेंटीमीटर-ग्राम-दूसरी प्रणाली में व्यक्त किया गया था।<ref name="GM">{{cite conference
जैसा कि विकिरण [[मात्रामापी]] का विज्ञान विकसित हुआ, यह महसूस किया गया कि आयनीकरण प्रभाव, और इसलिए ऊतक क्षति, अवशोषित ऊर्जा से जुड़ी थी, न कि केवल विकिरण खतरे से। परिणामस्वरूप, विकिरण सुरक्षा के लिए नई रेडियोमेट्रिक इकाइयां परिभाषित की गईं, जिन्होंने इसे ध्यान में रखा। 1953 में रेडिएशन यूनिट्स एंड मेजरमेंट्स (आईसीआरयू) पर अंतर्राष्ट्रीय आयोग ने नई विकिरण मात्रा अवशोषित अंश के माप की इकाई के रूप में 100 ईआरजी/ग्राम के बराबर रेड की सिफारिश की। रेड को इकाइयों की सुसंगत सेंटीमीटर-ग्राम-दूसरी प्रणाली में व्यक्त किया गया था।<ref name="GM">{{cite conference
|title = Dosimetry in Europe and the USSR
|title = Dosimetry in Europe and the USSR
|first1 = JH
|first1 = JH
Line 42: Line 40:
|access-date = 2012-05-15}}</ref>
|access-date = 2012-05-15}}</ref>


1975 में ईकाई [[ ग्रे (इकाई) |ग्रे (इकाई)]] को अवशोषित अंश की एसआई इकाई के रूप में नामित किया गया था। 1 ग्रे 1 जूल/किग्रा (अर्थात 100 रेड) के बराबर है। इसके अतिरिक्त, नई मात्रा, केर्मा (भौतिकी), को वायु आयनीकरण के लिए उपकरण अंशांकन के लिए खतरे के रूप में परिभाषित किया गया था, और इससे अवशोषित अंश की गणना विशिष्ट लक्ष्य सामग्री के लिए ज्ञात गुणांक का उपयोग करके की जा सकती है। आज, विकिरण सुरक्षा के लिए, आधुनिक इकाइयां, ऊर्जा अवशोषण के लिए अवशोषित अंश और स्टोकेस्टिक प्रभाव के लिए समतुल्य अंश ([[सीवर्ट]]) का अत्यधिक उपयोग किया जाता है, और रेंटजेन का उपयोग संभवतः ही कभी किया जाता है। बाट और माप की अंतर्राष्ट्रीय समिति (सीआईपीएम) ने कभी भी रॉन्टजेन के उपयोग को स्वीकार नहीं किया है।
1975 में ईकाई [[ ग्रे (इकाई) |ग्रे (इकाई)]] को अवशोषित अंश की एसआई इकाई के रूप में नामित किया गया था। 1 ग्रे 1 जूल/किग्रा (अर्थात 100 रेड) के समान है। इसके अतिरिक्त नई मात्रा, केर्मा (भौतिकी), को वायु आयनीकरण के लिए उपकरण अंशांकन के लिए खतरे के रूप में परिभाषित किया गया था, और इससे अवशोषित अंश की गणना विशिष्ट लक्ष्यों के पदार्थों के लिए ज्ञात गुणांक का उपयोग करके की जाती है। आज विकिरण सुरक्षा के लिए, आधुनिक इकाइयां, ऊर्जा अवशोषण के लिए अवशोषित अंश और स्टोकेस्टिक प्रभाव के लिए समतुल्य अंश ([[सीवर्ट]]) का अत्यधिक उपयोग किया जाता है, और रेंटजेन का उपयोग संभवतः ही कभी किया जाता है। इस प्रकार बाट और माप की अंतर्राष्ट्रीय समिति (सीआईपीएम) ने कभी भी रॉन्टजेन के उपयोग को स्वीकार नहीं किया है।
 
रॉन्टजेन को वर्षों से पुनर्परिभाषित किया गया है। इसे आखिरी बार 1998 में यू.एस. के राष्ट्रीय मानक और प्रौद्योगिकी संस्थान (एनआईएसटी) द्वारा परिभाषित किया गया था {{val|2.58|e=-4|ul=C|up=kg}}, इस अनुशंसा के साथ कि हर उस दस्तावेज़ में परिभाषा दी जाए जहाँ रेंटजेन का उपयोग किया जाता है।<ref name="fedreg63" />
 


रॉन्टजेन को वर्षों से पुनर्परिभाषित किया गया है। इसे आखिरी बार 1998 में यू.एस. के राष्ट्रीय मानक और प्रौद्योगिकी संस्थान (एनआईएसटी) द्वारा {{val|2.58|e=-4|ul=C|up=kg}} रूप से परिभाषित किया गया था, इस अनुशंसा के साथ कि हर उस दस्तावेज़ में परिभाषा दी जाए जहाँ रेंटजेन का उपयोग किया जाता है।<ref name="fedreg63" />
== इतिहास ==
== इतिहास ==
रेंटजेन की जड़ें 1908 में [[अमेरिकन रॉन्टजेन रे सोसाइटी]] द्वारा परिभाषित विलार्ड इकाई में हैं, जो विकिरण की मात्रा के रूप में है, जो आयनीकरण द्वारा प्रति घन सेंटीमीटर बिजली का स्टेटकूलम्ब मुक्त करता है|सेमी<sup>तापमान और दबाव की सामान्य परिस्थितियों में 3</sup> हवा।<ref name="VanLoon&VanTiggelen">Van Loon, R.; and Van Tiggelen, R., [http://www.radiology-museum.be/Pdf/RADIATIONDOSIMETRY.pdf ''Radiation Dosimetry in Medical Exposure: A Short Historical Overview''] {{webarchive|url=https://web.archive.org/web/20071024083402/http://www.radiology-museum.be/Pdf/RADIATIONDOSIMETRY.pdf |date=2007-10-24 }}, 2004></ref><ref>{{cite journal|title=Instruments de mesure à lecture directe pour les rayons x. Substitution de la méthode électrométrique aux autres méthodes de mesure en radiologie. Scleromètre et quantimètre.|journal=Archives d'électricité médicale|year=1908|volume=16|pages=692–699|location=Bordeaux}}</ref> 1 esu ≈ 3.33564 का उपयोग करना{{x10^|&minus;10}} सी और हवा का घनत्व ~1.293 किग्रा/मीटर<sup>3</sup> 0 °सी और 101 किलो पास्कल पर, यह 2.58 × 10 में बदल जाता है<sup>−4</sup> सी/किलोग्राम, जो एनआईएसटी द्वारा दिया गया आधुनिक मान है।
रेंटजेन मूल रूप से 1908 में [[अमेरिकन रॉन्टजेन रे सोसाइटी]] द्वारा परिभाषित विलार्ड इकाई में निहित किया गया हैं, जो विकिरण की मात्रा को प्रदर्शित करता है, यह इस प्रकार आयनीकरण द्वारा प्रति घन सेंटीमीटर विद्युत का स्टेटकूलम्ब मुक्त 3 सेमी तापमान और दबाव की सामान्य परिस्थितियों में वायु को प्रसारित करता है।<ref name="VanLoon&VanTiggelen">Van Loon, R.; and Van Tiggelen, R., [http://www.radiology-museum.be/Pdf/RADIATIONDOSIMETRY.pdf ''Radiation Dosimetry in Medical Exposure: A Short Historical Overview''] {{webarchive|url=https://web.archive.org/web/20071024083402/http://www.radiology-museum.be/Pdf/RADIATIONDOSIMETRY.pdf |date=2007-10-24 }}, 2004></ref><ref>{{cite journal|title=Instruments de mesure à lecture directe pour les rayons x. Substitution de la méthode électrométrique aux autres méthodes de mesure en radiologie. Scleromètre et quantimètre.|journal=Archives d'électricité médicale|year=1908|volume=16|pages=692–699|location=Bordeaux}}</ref> इस प्रकार 1 esu ≈ 3.33564{{x10^|&minus;10}} C का उपयोग करना और हवा का घनत्व ~1.293 किग्रा/मीटर<sup>3</sup> तापमान 0°C और दबाव 101 किलो पास्कल पर निहित रहता हैं, यह 2.58 × 10<sup>−4</sup> सी/किलोग्राम में परिवर्तित कर दिया जाता है, जो एनआईएसटी द्वारा दिया गया आधुनिक मान है।


1{{sfrac|esu|cm<sup>3</sup>}} × 3.33564 × 10<sup>−10</sup>{{sfrac|C|esu}} × 1,000,000 {{sfrac|cm<sup>3</sup>|m<sup>3</sup>}} ÷ 1.293 {{sfrac|kg|m<sup>3</sup>}} = 2.58 × 10<sup>-4</सुप>{{sfrac|C|kg}}
1{{sfrac|esu|cm<sup>3</sup>}} × 3.33564 × 10<sup>−10</sup>{{sfrac|C|esu}} × 1,000,000 {{sfrac|cm<sup>3</sup>|m<sup>3</sup>}} ÷ 1.293 {{sfrac|kg|m<sup>3</sup>}} = 2.58 × 10<sup>-4{{sfrac|C|kg}}


अगले 20 वर्षों के लिए इस परिभाषा का उपयोग विभिन्न नामों (ई, आर, और विकिरण की जर्मन इकाई) के अनुसार किया गया था। इस बीच, फ्रांसीसी रोएंटजेन को अलग परिभाषा दी गई, जो 0.444 जर्मन आर की राशि थी।
अगले 20 वर्षों के लिए इस परिभाषा का उपयोग विभिन्न नामों (ई, आर, और विकिरण की जर्मन इकाई) के अनुसार किया गया था। इस बीच, फ्रांसीसी रोएंटजेन को अलग परिभाषा दी गई, जो 0.444 जर्मन आर की राशि थी।


=== आईसीआर परिभाषाएं ===
=== आईसीआर परिभाषाएं ===
1928 में, [[रेडियोलॉजी की अंतर्राष्ट्रीय कांग्रेस]] (आईसीआर) ने एक्स-विकिरण की मात्रा के रूप में रॉन्टजेन को परिभाषित किया, जो कि जब द्वितीयक इलेक्ट्रॉनों का पूरी तरह से उपयोग किया जाता है और कक्ष की दीवार के प्रभाव से बचा जाता है, तो 0 डिग्री पर वायुमंडलीय हवा के 1 सीसी में उत्पादन होता है। सी और 76 सेमी पारा दबाव इस तरह की चालकता की डिग्री है कि 1 ईएसयू आवेश को संतृप्त धारा में मापा जाता है।<ref name="VanLoon&VanTiggelen" />बताई गई 1 सीसी हवा का द्रव्यमान 1.293 g होगा, इसलिए 1937 में आईसीआर ने आयतन, तापमान और दबाव के अतिरिक्त हवा के इस द्रव्यमान के संदर्भ में यह परिभाषा लिखी।<ref name="guill">{{cite conference|title = यूरोप और यूएसएसआर में डोसिमेट्री|first1 = JH|last1 = Guill|first2 =John|last2 = Moteff|page = 64|url = https://books.google.com/books?id=czTi4G6-Hq8C&pg=PA63|conference = Symposium on Radiation Effects and Dosimetry|publisher = ASTM International|lccn = 60-14734|location = Baltimore|date = June 1960|access-date = 15 May 2012}}</ref> 1937 की परिभाषा को गामा किरणों तक भी बढ़ाया गया था, किन्तु बाद में 1950 में इसे 3 MeV तक सीमित कर दिया गया।
1928 में, [[रेडियोलॉजी की अंतर्राष्ट्रीय कांग्रेस]] (आईसीआर) ने एक्स-विकिरण की मात्रा के रूप में रॉन्टजेन को परिभाषित किया गया था, जो कि इस प्रकार द्वितीयक इलेक्ट्रॉनों का पूर्ण रूप से उपयोग किया जाता है और कक्ष की दीवार के प्रभाव से बचा जाता है, तो इस प्रकार 0 डिग्री पर वायुमंडलीय हवा के 1 सीसी में उत्पादन होता है। 1 सी और 76 सेमी पारा दबाव इस प्रकार की चालकता की डिग्री है कि 1 ईएसयू आवेश को संतृप्त धारा में मापा जाता है।<ref name="VanLoon&VanTiggelen" /> इस प्रकार बताए गए 1 सीसी हवा का द्रव्यमान 1.293 ग्राम होगा, इसलिए 1937 में आईसीआर ने आयतन, तापमान और दबाव के अतिरिक्त हवा के इस द्रव्यमान के संदर्भ में यह परिभाषा लिखी गई थी।<ref name="guill">{{cite conference|title = यूरोप और यूएसएसआर में डोसिमेट्री|first1 = JH|last1 = Guill|first2 =John|last2 = Moteff|page = 64|url = https://books.google.com/books?id=czTi4G6-Hq8C&pg=PA63|conference = Symposium on Radiation Effects and Dosimetry|publisher = ASTM International|lccn = 60-14734|location = Baltimore|date = June 1960|access-date = 15 May 2012}}</ref> 1937 की परिभाषा को गामा किरणों तक भी बढ़ाया गया था, किन्तु बाद में 1950 में इसे 3 मेगा वोल्ट तक सीमित कर दिया गया था।


=== गोस्ट परिभाषा ===
=== गोस्ट परिभाषा ===
[[ सोवियत संघ | सोवियत संघ]] [[मानकों की अखिल-संघ समिति]] (GOST) ने इस बीच 1934 में रेंटजेन की अधिक अलग परिभाषा को अपनाया था। GOST मानक 7623 ने इसे एक्स-रे की भौतिक अंश के रूप में परिभाषित किया है जो प्रति सेमी परिमाण में इलेक्ट्रोस्टैटिक इकाई के प्रत्येक चार्ज का उत्पादन करता है।<sup>0 डिग्री सेल्सियस पर हवा में विकिरणित आयतन का 3</sup> और आयनीकरण पूर्ण होने पर सामान्य वायुमंडलीय दबाव।<ref>{{cite journal|last=Ardashnikov|first=S. N.|author2=Chetverikov, N. S. |title=The definition of the roentgen in the "Recommendations of the International Commission on Radiological Units. 1953"|journal=Atomic Energy|year=1957|volume=3|issue=9|pages=1027–1032|doi=10.1007/BF01515739|s2cid=95827816}}</ref> अंश से भौतिक अंश के भेद ने भ्रम उत्पन्न किया, जिनमें से कुछ ने कैंट्रिल और पार्कर की रिपोर्ट का नेतृत्व किया हो सकता है कि ऊतक के 83 ईआरजीएस प्रति ग्राम (0.0083 ग्रे (ईकाई)) के लिए रेंटजेन शॉर्टहैंड बन गया था।<ref>{{cite report |last1= Cantrill MD |first1= S.T. |last2= Parker |first2=H.M. |title= सहिष्णुता की खुराक|date= 1945-01-05 |url=https://apps.dtic.mil/sti/citations/ADA322447 |archive-url=https://web.archive.org/web/20210407155417/https://apps.dtic.mil/sti/citations/ADA322447 |url-status=live |archive-date=April 7, 2021 |access-date= 14 May 2012 |publisher= US Atomic Energy Commission, Argonne National Laboratory}}</ref> आईसीआर राॅन्टजेन से अलग करने के लिए उन्होंने इस व्युत्पन्न मात्रा को राॅन्टजेन समकक्ष भौतिक (rep) नाम दिया।
[[ सोवियत संघ |सोवियत संघ]] [[मानकों की अखिल-संघ समिति]] (जीओएसटी) ने इस बीच 1934 में रेंटजेन की अधिक अलग परिभाषा को अपनाया था। जीओएसटी मानक 7623<sup>0</sup> डिग्री सेल्सियस पर हवा में विकिरणित आयतन का 3 और आयनीकरण पूर्ण होने पर सामान्य वायुमंडलीय दबाव ने इसे एक्स-रे की भौतिक अंश के रूप में परिभाषित किया है जो इस प्रकार प्रति सेमी परिमाण में विद्युत स्थैतिक इकाई के प्रत्येक आवेश का उत्पादन करता है।<ref>{{cite journal|last=Ardashnikov|first=S. N.|author2=Chetverikov, N. S. |title=The definition of the roentgen in the "Recommendations of the International Commission on Radiological Units. 1953"|journal=Atomic Energy|year=1957|volume=3|issue=9|pages=1027–1032|doi=10.1007/BF01515739|s2cid=95827816}}</ref> इस अंश से भौतिक अंश के भेद ने भ्रम उत्पन्न किया गया था, जिनमें से कुछ ने कैंट्रिल और पार्कर की रिपोर्ट का नेतृत्व किया जा सकता है, इस प्रकार ऊतक के 83 ईआरजीएस प्रति ग्राम (0.0083 ग्रे (ईकाई)) के लिए रेंटजेन शॉर्टहैंड बन गया था।<ref>{{cite report |last1= Cantrill MD |first1= S.T. |last2= Parker |first2=H.M. |title= सहिष्णुता की खुराक|date= 1945-01-05 |url=https://apps.dtic.mil/sti/citations/ADA322447 |archive-url=https://web.archive.org/web/20210407155417/https://apps.dtic.mil/sti/citations/ADA322447 |url-status=live |archive-date=April 7, 2021 |access-date= 14 May 2012 |publisher= US Atomic Energy Commission, Argonne National Laboratory}}</ref> आईसीआर राॅन्टजेन से अलग करने के लिए उन्होंने इस व्युत्पन्न मात्रा को राॅन्टजेन समकक्ष भौतिक (आरईपी) नाम दिया था।


=== आईसीआरपी परिभाषा ===
=== आईसीआरपी परिभाषा ===
रॉन्टजेन मापन इकाई की शुरूआत, जो हवा के आयनीकरण को मापने पर निर्भर थी, ने पहले कम त्रुटिहीन प्रथाओं को बदल दिया जो समयबद्ध खतरे, फिल्म खतरे या प्रतिदीप्ति पर निर्भर थी।<ref>Mutscheller, A. (1925). Physical standards of protection against Roentgen ray dangers, AJR. American Journal of Roentgenology, 13, 65–69.</ref> इसने खतरे सीमा निर्धारित करने का मार्ग प्रशस्त किया, और [[संयुक्त राज्य अमेरिका]] के विकिरण संरक्षण और माप पर राष्ट्रीय परिषद ने 1931 में प्रति दिन 0.1 रॉन्टजेन के रूप में पहली औपचारिक अंश सीमा स्थापित की।<ref>{{cite conference |last= Meinhold |first= Charles B. |title= One Hundred Years of X Rays and Radioactivity – Radiation Protection: Then and Now |date= April 1996 |series= International Congress |url= http://www.irpa.net/irpa9/cdrom/VOL.1/V1_2.PDF |access-date= 14 May 2012 |publisher= International Radiation Protection Association |location= Vienna, Austria}}</ref> [[अंतर्राष्ट्रीय एक्स-रे और रेडियम संरक्षण समिति]], जिसे अब रेडियोलॉजिकल प्रोटेक्शन (आईसीआरपी) पर अंतर्राष्ट्रीय आयोग के रूप में जाना जाता है, ने जल्द ही 1934 में प्रति दिन 0.2 रेंटजेन की सीमा का पालन किया।<ref>{{cite journal|last=Clarke|first=R.H.|author2=J. Valentin |title=ICRP का इतिहास और इसकी नीतियों का विकास|journal=Annals of the ICRP|year=2009|volume=39|series=ICRP Publication 109|issue=1|pages=75–110|doi=10.1016/j.icrp.2009.07.009|s2cid=71278114|url=http://www.icrp.org/docs/The%20History%20of%20ICRP%20and%20the%20Evolution%20of%20its%20Policies.pdf|access-date=12 May 2012}}</ref> 1950 में, आईसीआरपी ने पूरे शरीर के खतरे के लिए उनकी अनुशंसित सीमा को घटाकर प्रति सप्ताह 0.3 रेंटजेन कर दिया।
रॉन्टजेन मापन इकाई के प्रारंभ में हवा के आयनीकरण को मापने पर निर्भर थी, इसने पहले कम त्रुटिहीन प्रथाओं को परिवर्तित कर दिया जो समयबद्ध खतरे, फिल्म खतरे या प्रतिदीप्ति पर निर्भर करती थी।<ref>Mutscheller, A. (1925). Physical standards of protection against Roentgen ray dangers, AJR. American Journal of Roentgenology, 13, 65–69.</ref> इसने खतरे की सीमा को निर्धारित करने का मार्ग प्रशस्त किया, और इस प्रकार [[संयुक्त राज्य अमेरिका]] के विकिरण संरक्षण और माप पर राष्ट्रीय परिषद ने 1931 में प्रति दिन 0.1 रॉन्टजेन के रूप में पहली औपचारिक अंश सीमा स्थापित किया था।<ref>{{cite conference |last= Meinhold |first= Charles B. |title= One Hundred Years of X Rays and Radioactivity – Radiation Protection: Then and Now |date= April 1996 |series= International Congress |url= http://www.irpa.net/irpa9/cdrom/VOL.1/V1_2.PDF |access-date= 14 May 2012 |publisher= International Radiation Protection Association |location= Vienna, Austria}}</ref> इस प्रकार [[अंतर्राष्ट्रीय एक्स-रे और रेडियम संरक्षण समिति]], जिसे अब रेडियोलॉजिकल प्रोटेक्शन (आईसीआरपी) पर अंतर्राष्ट्रीय आयोग के रूप में जाना जाता है, इसने शीघ्र ही 1934 में प्रति दिन 0.2 रेंटजेन की सीमा का पालन किया था।<ref>{{cite journal|last=Clarke|first=R.H.|author2=J. Valentin |title=ICRP का इतिहास और इसकी नीतियों का विकास|journal=Annals of the ICRP|year=2009|volume=39|series=ICRP Publication 109|issue=1|pages=75–110|doi=10.1016/j.icrp.2009.07.009|s2cid=71278114|url=http://www.icrp.org/docs/The%20History%20of%20ICRP%20and%20the%20Evolution%20of%20its%20Policies.pdf|access-date=12 May 2012}}</ref> इस प्रकार 1950 में, आईसीआरपी ने पूरे शरीर के खतरे के लिए उनकी अनुशंसित सीमा को घटाकर प्रति सप्ताह 0.3 रेंटजेन कर दिया था।
 
विकिरण इकाइयों और मापन पर अंतर्राष्ट्रीय आयोग (आईसीआरयू) ने 1950 में रेंटजेन की परिभाषा को अपने हाथ में ले लिया, इसे X या γ-विकिरण की मात्रा के रूप में परिभाषित किया, जैसे कि हवा में प्रति 0.001293 ग्राम वायु से संबंधित कॉर्पसकुलर उत्सर्जन, हवा में, आयनों को ले जाता है। किसी भी संकेत की बिजली की मात्रा की 1 इलेक्ट्रोस्टैटिक इकाई।<ref>{{cite book|title=रेडियोलॉजिकल प्रोटेक्शन पर अंतर्राष्ट्रीय आयोग और रेडियोलॉजिकल यूनिट्स पर अंतर्राष्ट्रीय आयोग की सिफारिशें|year=1950|publisher=US Department of Commerce|url=http://www.orau.org/ptp/Library/NBS/NBS%2047.pdf|access-date=14 November 2012|series=National Bureau of Standards Handbook|volume=47}}</ref> 3 मेव कैप अब परिभाषा का हिस्सा नहीं था, किन्तु उच्च बीम ऊर्जा पर इस इकाई की निम्नीकृत उपयोगिता का उल्लेख साथ के पाठ में किया गया था। इस बीच, रॉन्टजेन समतुल्य पुरुष (रेम) की नई अवधारणा विकसित की गई थी।
 
1957 से प्रारंभ होकर, आईसीआरपी ने रेम के संदर्भ में अपनी सिफारिशें प्रकाशित करना प्रारंभ किया, और रॉन्टजेन अनुपयोगी हो गया। चिकित्सा इमेजिंग समुदाय को अभी भी आयनीकरण माप की आवश्यकता है, किन्तु वे धीरे-धीरे सी / किग्रा का उपयोग करने के लिए परिवर्तित हो गए क्योंकि विरासत उपकरण को बदल दिया गया था।<ref name="CarltonAdler2012">{{cite book|last1=Carlton|first1=Richard R. |last2=Adler|first2=Arlene McKenna |title=Principles of Radiographic Imaging: An Art and a Science|chapter-url=https://books.google.com/books?id=5mbrJ43Oo7IC&pg=PA145|access-date=12 May 2012|edition=5th|date=1 January 2012|publisher=Cengage Learning|isbn=978-1-4390-5872-5|page=145|chapter=Radiation Protection Concepts and Equipment}}</ref> आईसीआरयू ने रेंटजेन को ठीक 2.58 × 10 के रूप में पुनर्परिभाषित करने की सिफारिश की<sup>−4</sup> सी/किलोग्राम 1971 में।<ref>ICRU Report 19, 1971</ref>


विकिरण इकाइयों और मापन पर अंतर्राष्ट्रीय आयोग (आईसीआरयू) ने 1950 में रेंटजेन की परिभाषा को अपने हाथ में ले लिया था, इसे X या γ-विकिरण की मात्रा के रूप में परिभाषित किया, जैसे कि हवा में प्रति 0.001293 ग्राम वायु से संबंधित कॉर्पसकुलर उत्सर्जन, हवा में, आयनों को ले जाता है। किसी भी संकेत की विद्युत की मात्रा की 1 विद्युत स्थैतिक इकाई के रूप में माना जाता हैं।<ref>{{cite book|title=रेडियोलॉजिकल प्रोटेक्शन पर अंतर्राष्ट्रीय आयोग और रेडियोलॉजिकल यूनिट्स पर अंतर्राष्ट्रीय आयोग की सिफारिशें|year=1950|publisher=US Department of Commerce|url=http://www.orau.org/ptp/Library/NBS/NBS%2047.pdf|access-date=14 November 2012|series=National Bureau of Standards Handbook|volume=47}}</ref> 3 मेव कैप अब परिभाषा का भाग नहीं था, किन्तु उच्च बीम ऊर्जा पर इस इकाई की निम्नीकृत उपयोगिता का उल्लेख साथ के पाठ में किया गया था। इस बीच रॉन्टजेन समतुल्य मानव (रेम) की नई अवधारणा विकसित की गई थी।


1957 से प्रारंभ होकर, आईसीआरपी ने रेम के संदर्भ में अपने प्रस्तावों को प्रकाशित करना प्रारंभ किया था, और रॉन्टजेन के लिए यह अनुपयोगी हो गया। चिकित्सा इमेजिंग समुदाय को अभी भी आयनीकरण माप की आवश्यकता है, किन्तु वे धीरे-धीरे 1 सी/किग्रा का उपयोग करने के लिए परिवर्तित हो गए क्योंकि विरासत उपकरण को परिवर्तित कर दिया गया था।<ref name="CarltonAdler2012">{{cite book|last1=Carlton|first1=Richard R. |last2=Adler|first2=Arlene McKenna |title=Principles of Radiographic Imaging: An Art and a Science|chapter-url=https://books.google.com/books?id=5mbrJ43Oo7IC&pg=PA145|access-date=12 May 2012|edition=5th|date=1 January 2012|publisher=Cengage Learning|isbn=978-1-4390-5872-5|page=145|chapter=Radiation Protection Concepts and Equipment}}</ref> आईसीआरयू ने रेंटजेन को ठीक 2.58 × 10<sup>−4</sup> सी/किलोग्राम 1971 में इसके रूप में पुनर्परिभाषित करने का प्रस्ताव रखा था।<ref>ICRU Report 19, 1971</ref>
=== यूरोपीय संघ ===
=== यूरोपीय संघ ===
1971 में [[यूरोपीय आर्थिक समुदाय]], माप निर्देशों की यूरोपीय इकाइयों में। निर्देश 71/354/ईईसी, माप की उन इकाइयों को सूचीबद्ध करता है जिनका उपयोग ... सार्वजनिक स्वास्थ्य ... उद्देश्यों के लिए किया जा सकता है।<ref>{{cite web
1971 में [[यूरोपीय आर्थिक समुदाय|यूरोपीय आर्थिक संघ]], माप निर्देशों की यूरोपीय इकाइयों में इसका उपयोग किया था। इसके निर्देशानुसार 71/354/ईईसी, माप की उन इकाइयों को सूचीबद्ध करता है, जिनका उपयोग ... सार्वजनिक स्वास्थ्य ... उद्देश्यों के लिए किया जा सकता है।<ref>{{cite web
|url=http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=DD:I:1971_III:31971L0354:EN:PDF
|url=http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=DD:I:1971_III:31971L0354:EN:PDF
|title=Council Directive 71/354/EEC: On the approximation of the laws of the Member States relating to units of measurement |publisher=The Council of the European Communities
|title=Council Directive 71/354/EEC: On the approximation of the laws of the Member States relating to units of measurement |publisher=The Council of the European Communities
|date=18 October 1971
|date=18 October 1971
|access-date=19 May 2012}}</ref> निर्देश में [[ क्यूरी (इकाई) |क्यूरी (इकाई)]] , रेड (ईकाई), [[ वास्तविक (इकाई) |वास्तविक (इकाई)]] और रेंटजेन को अनुमेय इकाइयों के रूप में सम्मिलित किया गया था, किन्तु यह आवश्यक था कि रेड, रेम और रेंटजेन के उपयोग की 31 दिसंबर 1977 से पहले समीक्षा की जाए। इस दस्तावेज़ ने रेंटजेन को परिभाषित किया बिल्कुल 2.58 × 10<sup>-4</sup> सी/किलोग्राम, आईसीआरयू की सिफारिश के अनुसार। मापन निर्देशों की यूरोपीय इकाइयाँ | निर्देश 80/181/ईईसी, दिसंबर 1979 में प्रकाशित, जिसने निर्देश 71/354/ईईसी को प्रतिस्थापित किया, इस उद्देश्य के लिए स्पष्ट रूप से ग्रे (ईकाई), [[ Becquerel |बैक्यूएरेल]] और सीवर्ट को सूचीबद्ध किया और आवश्यक किया कि क्यूरी, रेड, रेम और रॉन्टजेन को 31 दिसंबर 1985 तक समाप्त कर दिया जाएगा।<ref>{{cite web
|access-date=19 May 2012}}</ref> इन निर्देशों में [[ क्यूरी (इकाई) |क्यूरी (इकाई)]] , रेड (ईकाई), [[ वास्तविक (इकाई) |वास्तविक (इकाई)]] और रेंटजेन को अनुमेय इकाइयों के रूप में सम्मिलित किया गया था, किन्तु यह आवश्यक था कि रेड, रेम और रेंटजेन के उपयोग की 31 दिसंबर 1977 से पहले समीक्षा की जाए। इस दस्तावेज़ ने रेंटजेन को परिभाषित किया था, जो बिल्कुल 2.58 × 10<sup>-4</sup> सी/किलोग्राम, आईसीआरयू के परामर्श के अनुसार मापन निर्देशों की यूरोपीय इकाइयाँ इसके निर्देशों के अनुसार 80/181/ईईसी, दिसंबर 1979 में प्रकाशित किया गया था, इस प्रकार जिसने इस निर्देश 71/354/ईईसी को प्रतिस्थापित किया, इस उद्देश्य के लिए स्पष्ट रूप से ग्रे (ईकाई), [[ Becquerel |बैक्यूएरेल]] और सीवर्ट को सूचीबद्ध किया था और आवश्यक किया कि क्यूरी, रेड, रेम और रॉन्टजेन को 31 दिसंबर 1985 तक समाप्त कर दिया जाएगा।<ref>{{cite web
| url = http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=CELEX:31980L0181:EN:NOT
| url = http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=CELEX:31980L0181:EN:NOT
| author = The Council of the European Communities
| author = The Council of the European Communities
Line 79: Line 73:
| date=1979-12-21
| date=1979-12-21
| access-date=19 May 2012}}</ref>
| access-date=19 May 2012}}</ref>
=== एनआईएसटी परिभाषा ===
=== एनआईएसटी परिभाषा ===
आज रॉन्टजेन का उपयोग संभवतः ही कभी किया जाता है, और वज़न और माप के लिए अंतर्राष्ट्रीय समिति (सीआईपीएम) ने रॉन्टजेन के उपयोग को कभी स्वीकार नहीं किया। 1977 से 1998 तक, यूएस एनआईएसटी के एसआई ब्रोशर के अनुवाद में कहा गया है कि सीआईपीएम ने अस्थायी रूप से 1969 से एसआई इकाइयों के साथ राॅन्टजेन (और अन्य रेडियोलॉजी इकाइयों) के उपयोग को स्वीकार कर लिया है।<ref>{{cite book|author=International Bureau of Weights and Measures|editor=United States National Bureau of Standards|title=इकाइयों की अंतर्राष्ट्रीय प्रणाली (एसआई)|url=https://archive.org/details/bub_gb_YvZNdSdeCnEC|page=[https://archive.org/details/bub_gb_YvZNdSdeCnEC/page/n40 12]|access-date=18 May 2012|series=NBS Special Publication 330|year=1977|publisher=Dept. of Commerce, National Bureau of Standards}}</ref> चूंकि, परिशिष्ट में दिखाया गया एकमात्र संबंधित सीआईपीएम निर्णय 1964 में क्यूरी (ईकाई) के संबंध में है। एनआईएसटी ब्रोशर ने रेंटजेन को 2.58 × 10<sup>−4</sup> सी/किलोग्राम के रूप में परिभाषित किया है कि x या γ विकिरण के खतरे के साथ नियोजित किया जाना है, किन्तु आयनित होने के माध्यम को नहीं बताया। सीआईपीएम का वर्तमान एसआई ब्रोशर एसआई के साथ उपयोग के लिए स्वीकृत गैर-एसआई इकाइयों की तालिका से रेंटजेन को बाहर करता है।<ref>{{SIbrochure8th}}</ref> यूएस एनआईएसटी ने 1998 में स्पष्ट किया कि वह एसआई प्रणाली की अपनी व्याख्या प्रदान कर रहा था, जिससे उसने एसआई के साथ अमेरिका में उपयोग के लिए रॉन्टजेन को स्वीकार किया, जबकि यह स्वीकार किया कि सीआईपीएम ने नहीं किया।<ref>{{cite journal|last=Lyons|first=John W.|title=Metric System of Measurement: Interpretation of the International System of Units for the United States|journal=Federal Register|date=1990-12-20|volume=55|issue=245|pages=52242–52245|publisher=US Office of the Federal Register}}</ref> तब तक, एक्स और γ विकिरण की सीमा हटा दी गई थी। एनआईएसटी अनुशंसा करता है कि जहां इस इकाई का उपयोग किया जाता है वहां प्रत्येक दस्तावेज़ में रॉन्टजेन को परिभाषित किया जाए।<ref name="fedreg63">{{cite journal|last=Hebner|first=Robert E.|title=Metric System of Measurement: Interpretation of the International System of Units for the United States|journal=Federal Register|date=1998-07-28|volume=63|issue=144|page=40339|url=http://www.gpo.gov/fdsys/pkg/FR-1998-07-28/pdf/98-16965.pdf|access-date=9 May 2012|publisher=US Office of the Federal Register}}</ref> एनआईएसटी द्वारा रॉन्टजेन के निरंतर उपयोग को दृढ़ता से हतोत्साहित किया जाता है।<ref name=NIST>{{cite book|last1=Thompson|first1=Ambler|last2=Taylor|first2=Barry N.|title=इकाइयों की अंतर्राष्ट्रीय प्रणाली (एसआई) के उपयोग के लिए मार्गदर्शिका|year=2008|publisher=[[National Institute of Standards and Technology]]|location=Gaithersburg, MD|url=https://www.nist.gov/pml/pubs/sp811/index.cfm|edition=2008|access-date=28 November 2012|archive-url=https://web.archive.org/web/20080516081348/http://www.physics.nist.gov/Pubs/SP811/sec05.html|id=SP811|page=10|archive-date=16 May 2008|url-status=live}}</ref>
आज रॉन्टजेन का उपयोग संभवतः ही कभी किया जाता है, और इस प्रकार वज़न और माप के लिए अंतर्राष्ट्रीय समिति (सीआईपीएम) ने रॉन्टजेन के उपयोग को कभी स्वीकार नहीं किया था। 1977 से 1998 तक, यूएस '''एनआईएसटी''' के एसआई ब्रोशर के अनुवाद में कहा गया है कि सीआईपीएम ने अस्थायी रूप से 1969 से एसआई इकाइयों के साथ राॅन्टजेन (और अन्य रेडियोलॉजी इकाइयों) के उपयोग को स्वीकार कर लिया है।<ref>{{cite book|author=International Bureau of Weights and Measures|editor=United States National Bureau of Standards|title=इकाइयों की अंतर्राष्ट्रीय प्रणाली (एसआई)|url=https://archive.org/details/bub_gb_YvZNdSdeCnEC|page=[https://archive.org/details/bub_gb_YvZNdSdeCnEC/page/n40 12]|access-date=18 May 2012|series=NBS Special Publication 330|year=1977|publisher=Dept. of Commerce, National Bureau of Standards}}</ref> चूंकि, परिशिष्ट में दिखाया गया एकमात्र संबंधित सीआईपीएम निर्णय 1964 में क्यूरी (ईकाई) के संबंध में है। इस प्रकार एनआईएसटी ब्रोशर ने रेंटजेन को 2.58 × 10<sup>−4</sup> सी/किलोग्राम के रूप में परिभाषित किया है कि x या γ विकिरण के खतरे के साथ नियोजित किया जाना है, किन्तु आयनित होने के माध्यम को नहीं बताया था। इस प्रकार सीआईपीएम का वर्तमान एसआई ब्रोशर एसआई के साथ उपयोग के लिए स्वीकृत गैर-एसआई इकाइयों की सूची से रेंटजेन को बाहर करता है।<ref>{{SIbrochure8th}}</ref> इस प्रकार यूएस एनआईएसटी ने 1998 में स्पष्ट किया कि वह एसआई प्रणाली की अपनी व्याख्या प्रदान कर रहा था, जिससे उसने एसआई के साथ अमेरिका में उपयोग के लिए रॉन्टजेन को स्वीकार किया था, जबकि यह स्वीकार किया कि सीआईपीएम ने नहीं किया।<ref>{{cite journal|last=Lyons|first=John W.|title=Metric System of Measurement: Interpretation of the International System of Units for the United States|journal=Federal Register|date=1990-12-20|volume=55|issue=245|pages=52242–52245|publisher=US Office of the Federal Register}}</ref> तब तक, X और γ विकिरण की सीमा हटा दी गई थी। एनआईएसटी अनुशंसा करता है कि जहां इस इकाई का उपयोग किया जाता है वहां प्रत्येक दस्तावेज़ में रॉन्टजेन को परिभाषित किया जाता हैं।<ref name="fedreg63">{{cite journal|last=Hebner|first=Robert E.|title=Metric System of Measurement: Interpretation of the International System of Units for the United States|journal=Federal Register|date=1998-07-28|volume=63|issue=144|page=40339|url=http://www.gpo.gov/fdsys/pkg/FR-1998-07-28/pdf/98-16965.pdf|access-date=9 May 2012|publisher=US Office of the Federal Register}}</ref> एनआईएसटी द्वारा रॉन्टजेन के निरंतर उपयोग को दृढ़ता से हतोत्साहित किया जाता है।<ref name=NIST>{{cite book|last1=Thompson|first1=Ambler|last2=Taylor|first2=Barry N.|title=इकाइयों की अंतर्राष्ट्रीय प्रणाली (एसआई) के उपयोग के लिए मार्गदर्शिका|year=2008|publisher=[[National Institute of Standards and Technology]]|location=Gaithersburg, MD|url=https://www.nist.gov/pml/pubs/sp811/index.cfm|edition=2008|access-date=28 November 2012|archive-url=https://web.archive.org/web/20080516081348/http://www.physics.nist.gov/Pubs/SP811/sec05.html|id=SP811|page=10|archive-date=16 May 2008|url-status=live}}</ref>
 
 
== प्रतिस्थापन रेडियोमेट्रिक मात्राओं का विकास ==
== प्रतिस्थापन रेडियोमेट्रिक मात्राओं का विकास ==
[[File:Dose quantities and units.png|thumb|400px|रेडियोलॉजिकल सुरक्षा में उपयोग की जाने वाली बाहरी आधुनिक विकिरण मात्रा]]चूंकि वायु आयन कक्ष के साथ मापने के लिए सुविधाजनक मात्रा, रेंटजेन का हानि था कि यह एक्स-रे की तीव्रता या उनके अवशोषण का प्रत्यक्ष माप नहीं था, बल्कि एक्स-रे के आयनिंग प्रभाव का माप था विशिष्ट परिस्थिति; जो 0 डिग्री सेल्सियस पर शुष्क हवा थी और दबाव का 1 [[मानक दबाव]] था।<ref name=Lovell4>{{cite book
[[File:Dose quantities and units.png|thumb|400px|रेडियोलॉजिकल सुरक्षा में उपयोग की जाने वाली बाहरी आधुनिक विकिरण मात्रा]]चूंकि वायु आयन कक्ष के साथ मापने के लिए सुविधाजनक मात्रा, रेंटजेन का हानि था कि यह एक्स-रे की तीव्रता या उनके अवशोषण का प्रत्यक्ष माप नहीं था, बल्कि एक्स-रे के आयनिंग प्रभाव का माप था, इस प्रकार विशिष्ट परिस्थिति में 0 डिग्री सेल्सियस पर शुष्क हवा थी और दबाव का 1 [[मानक दबाव]] पर स्थिति किया गया था।<ref name=Lovell4>{{cite book
|chapter-url =https://books.google.com/books?id=lK48AAAAIAAJ&q=roentgen+defined&pg=PA56
|chapter-url =https://books.google.com/books?id=lK48AAAAIAAJ&q=roentgen+defined&pg=PA56
|title = An introduction to Radiation Dosimetry
|title = An introduction to Radiation Dosimetry
Line 97: Line 87:
|publisher = Cambridge University Press
|publisher = Cambridge University Press
|access-date = 2012-05-15}}</ref>
|access-date = 2012-05-15}}</ref>
इस वजह से रेंटजेन का लक्ष्य सामग्री में प्रति इकाई द्रव्यमान में अवशोषित ऊर्जा की मात्रा के लिए चर संबंध था, क्योंकि विभिन्न सामग्रियों में अलग-अलग अवशोषण विशेषताएँ होती हैं। जैसा कि विकिरण डोसिमेट्री का विज्ञान विकसित हुआ, इसे गंभीर कमी के रूप में देखा गया।
इस कारण रेंटजेन का लक्ष्य पदार्थों में प्रति इकाई द्रव्यमान में अवशोषित ऊर्जा की मात्रा के लिए वैरियेबल से संयोजित था, क्योंकि विभिन्न पदार्थों में अलग-अलग अवशोषण विशेषताएँ होती हैं। जैसा कि विकिरण डोसिमेट्री का विज्ञान विकसित हुआ, इसे गंभीर कमी के रूप में देखा गया।


1940 में, [[लुई हेरोल्ड ग्रे]], जो मानव ऊतक पर न्यूट्रॉन क्षति के प्रभाव का अध्ययन कर रहे थे, [[विलियम वेलेंटाइन मेनॉर्ड]] और रेडियोबायोलॉजिस्ट जॉन रीड के साथ मिलकर पेपर प्रकाशित किया जिसमें माप की इकाई ने ग्राम रेंटजेन (प्रतीक: जीआर) को डब किया। न्यूट्रॉन विकिरण की उस मात्रा के रूप में परिभाषित किया गया है जो विकिरण के रेंटजेन द्वारा पानी की इकाई मात्रा में उत्पादित ऊर्जा की वृद्धि के बराबर ऊतक की इकाई मात्रा में ऊर्जा में वृद्धि का उत्पादन करती है।<ref name="Gupta2009">{{cite book|last=Gupta|first=S. V. |title=Units of Measurement: Past, Present and Future : International System of Units|chapter-url=https://books.google.com/books?id=pHiKycrLmEQC&pg=PA144|access-date=2012-05-14|date=2009-11-19|publisher=Springer|isbn=978-3-642-00737-8|page=144|chapter=Louis Harold Gray}}</ref> प्रस्तावित किया गया था। यह इकाई हवा में 88 ईआरजीएस के बराबर पाई गई। 1953 में आईसीआरयू ने अवशोषित विकिरण के माप की नई इकाई के रूप में 100 ईआरजी/ग्राम के बराबर रेड (ईकाई) की सिफारिश की। रेड को सुसंगत [[सीजीएस प्रणाली]] इकाइयों में व्यक्त किया गया था।<ref>Guill, JH; Moteff, John (June 1960). "Dosimetry in Europe and the USSR". Third Pacific Area Meeting Papers — Materials in Nuclear Applications. Symposium on Radiation Effects and Dosimetry - Third Pacific Area Meeting American Society for Testing Materials, October 1959, San Francisco, 12–16 October 1959. American Society Technical Publication. 276. ASTM International. p. 64. LCCN 60014734. Retrieved 2012-05-15.</ref>
1940 में, [[लुई हेरोल्ड ग्रे]], जो मानव ऊतक पर न्यूट्रॉन क्षति के प्रभाव का अध्ययन कर रहे थे, [[विलियम वेलेंटाइन मेनॉर्ड]] और रेडियोबायोलॉजिस्ट जॉन रीड के साथ मिलकर पेपर प्रकाशित किया था, जिसमें माप की इकाई ने ग्राम रेंटजेन (प्रतीक: जीआर) को डब किया था। न्यूट्रॉन विकिरण की उस मात्रा के रूप में परिभाषित किया गया है, जो विकिरण के रेंटजेन द्वारा पानी की इकाई मात्रा में उत्पादित ऊर्जा की वृद्धि के बराबर ऊतक की इकाई मात्रा में ऊर्जा में वृद्धि का उत्पादन करती है।<ref name="Gupta2009">{{cite book|last=Gupta|first=S. V. |title=Units of Measurement: Past, Present and Future : International System of Units|chapter-url=https://books.google.com/books?id=pHiKycrLmEQC&pg=PA144|access-date=2012-05-14|date=2009-11-19|publisher=Springer|isbn=978-3-642-00737-8|page=144|chapter=Louis Harold Gray}}</ref> इस प्रकार यह प्रस्तावित किया गया था कि यह इकाई हवा में 88 ईआरजीएस के बराबर पाई गई थी। 1953 में आईसीआरयू ने अवशोषित विकिरण के माप की नई इकाई के रूप में 100 ईआरजी/ग्राम के बराबर रेड (ईकाई) की सिफारिश की। रेड को सुसंगत [[सीजीएस प्रणाली]] इकाइयों में व्यक्त किया गया था।<ref>Guill, JH; Moteff, John (June 1960). "Dosimetry in Europe and the USSR". Third Pacific Area Meeting Papers — Materials in Nuclear Applications. Symposium on Radiation Effects and Dosimetry - Third Pacific Area Meeting American Society for Testing Materials, October 1959, San Francisco, 12–16 October 1959. American Society Technical Publication. 276. ASTM International. p. 64. LCCN 60014734. Retrieved 2012-05-15.</ref>


1950 के दशक के उत्तरार्ध में वजन और माप पर सामान्य सम्मेलन (सीजीपीएम) ने आईसीआरयू को अन्य वैज्ञानिक निकायों में सम्मिलित होने के लिए आमंत्रित किया जिससे कि वे इकाइयों की प्रणाली के विकास में वजन और माप के लिए अंतर्राष्ट्रीय समिति (सीआईपीएम) के साथ काम कर सकें जो कि कई पर लगातार उपयोग किया जा सकता है। विषयों। यह निकाय, जिसे प्रारंभ में इकाइयों की प्रणाली के लिए आयोग के रूप में जाना जाता था, जिसका नाम 1964 में इकाइयों के लिए सलाहकार समिति (सीसीयू) के रूप में बदल दिया गया, अंतर्राष्ट्रीय प्रणाली इकाइयों (एसआई) के विकास की देखरेख के लिए जिम्मेदार था।<ref>{{cite web
1950 के दशक के उत्तरार्ध में भार और माप पर सामान्य सम्मेलन (सीजीपीएम) ने आईसीआरयू को अन्य वैज्ञानिक निकायों में सम्मिलित होने के लिए आमंत्रित किया जिससे कि वे इकाइयों की प्रणाली के विकास में भार और माप के लिए अंतर्राष्ट्रीय समिति (सीआईपीएम) के साथ कार्य कर सकें जो कि विभिन्न रूपों में निरंतर उपयोग किया जा सकता है। इस प्रकार यह निकाय प्रारंभ में इकाइयों की प्रणाली के लिए आयोग के रूप में जाना जाता था, जिसका नाम 1964 में इकाइयों के लिए सलाहकार समिति (सीसीयू) के रूप में परिवर्तित कर दिया गया था, इस प्रकार अंतर्राष्ट्रीय प्रणाली इकाइयों (एसआई) के विकास की देखरेख के लिए जिम्मेदार था।<ref>{{cite web
|url = http://www.bipm.org/en/committees/cc/ccu/
|url = http://www.bipm.org/en/committees/cc/ccu/
|title = CCU: Consultative Committee for Units
|title = CCU: Consultative Committee for Units
|publisher = [[International Bureau of Weights and Measures]] (BIPM)
|publisher = [[International Bureau of Weights and Measures]] (BIPM)
|access-date = 2012-05-18}}</ref> उसी समय यह तेजी से स्पष्ट होता जा रहा था कि रेंटजेन की परिभाषा गलत थी, और 1962 में इसे फिर से परिभाषित किया गया।<ref>{{cite book
|access-date = 2012-05-18}}</ref> उसी समय यह तेजी से स्पष्ट होता जा रहा था कि रेंटजेन की परिभाषा गलत थी, और 1962 में इसे फिर से परिभाषित किया गया था।<ref>{{cite book
|chapter-url = https://books.google.com/books?id=IEhJpyEBKYIC&q=roentgen+1925+1937+1962+ionisation&pg=PA554
|chapter-url = https://books.google.com/books?id=IEhJpyEBKYIC&q=roentgen+1925+1937+1962+ionisation&pg=PA554
|title = The Dental Assistant
|title = The Dental Assistant
Line 119: Line 109:
}}</ref>
}}</ref>


सीसीयू ने अवशोषित विकिरण की एसआई इकाई को प्रति इकाई द्रव्यमान ऊर्जा के रूप में परिभाषित करने का निर्णय लिया, जो एमकेएस इकाइयों में जूल/किलोग्राम था। इसकी पुष्टि 1975 में 15वें सीजीपीएम द्वारा की गई थी, और ईकाई का नाम लुई हेरोल्ड ग्रे के सम्मान में ग्रे रखा गया था, जिनकी मृत्यु 1965 में हुई थी। ग्रे 100 रेड के बराबर था। रॉन्टजन की परिभाषा में हवा में फोटॉनों को परिभाषित करने के लिए अपेक्षाकृत सरल होने का आकर्षण था, किन्तु ग्रे प्राथमिक आयनीकरण विकिरण प्रकार से स्वतंत्र है, और इसका उपयोग केर्मा और अवशोषित अंश दोनों के लिए व्यापक श्रेणी के मामले में किया जा सकता है।<ref name="Lovell3">{{cite book
सीसीयू ने अवशोषित विकिरण की एसआई इकाई को प्रति इकाई द्रव्यमान ऊर्जा के रूप में परिभाषित करने का निर्णय लिया, जो एमकेएस इकाइयों में जूल/किलोग्राम था। इसकी पुष्टि 1975 में 15वें सीजीपीएम द्वारा की गई थी, और इस प्रकार इस ईकाई का नाम लुई हेरोल्ड ग्रे के सम्मान में ग्रे रखा गया था, जिनकी मृत्यु 1965 में हुई थी। यह ग्रे 100 रेड के बराबर था। रॉन्टजन की परिभाषा में हवा में फोटॉनों को परिभाषित करने के लिए अपेक्षाकृत सरल होने का आकर्षण था, किन्तु ग्रे प्राथमिक आयनीकरण विकिरण प्रकार से स्वतंत्र है, और इसका उपयोग केर्मा और अवशोषित अंश दोनों के लिए व्यापक श्रेणी की स्थिति में किया जा सकता है।<ref name="Lovell3">{{cite book
|chapter-url =https://books.google.com/books?id=lK48AAAAIAAJ&q=roentgen+defined&pg=PA56
|chapter-url =https://books.google.com/books?id=lK48AAAAIAAJ&q=roentgen+defined&pg=PA56
|title = An introduction to Radiation Dosimetry
|title = An introduction to Radiation Dosimetry
Line 131: Line 121:
|access-date = 2012-05-15}}</ref>
|access-date = 2012-05-15}}</ref>


बाहरी खतरे के कारण मानव में अवशोषित अंश को मापते समय, एसआई इकाई ग्रे (ईकाई), या संबंधित गैर-एसआई रेड (ईकाई) का उपयोग किया जाता है। इनमें से अलग-अलग विकिरण प्रकारों और लक्ष्य सामग्री से जैविक प्रभावों पर विचार करने के लिए अंश समकक्ष विकसित किए जा सकते हैं। ये समकक्ष अंश और [[प्रभावी खुराक (विकिरण)|प्रभावी अंश (विकिरण)]] हैं जिसके लिए एसआई ईकाई सीवर्ट या गैर-एसआई रेंटजेन समकक्ष मैन का उपयोग किया जाता है।
बाहरी खतरे के कारण मानव में अवशोषित अंश को मापते समय, एसआई इकाई ग्रे (ईकाई), या संबंधित गैर-एसआई रेड (ईकाई) का उपयोग किया जाता है। इनमें से अलग-अलग विकिरण प्रकारों और लक्ष्य पदार्थ से जैविक प्रभावों पर विचार करने के लिए अंश समकक्ष विकसित किए जा सकते हैं। ये समकक्ष अंश और [[प्रभावी खुराक (विकिरण)|प्रभावी अंश (विकिरण)]] हैं जिसके लिए एसआई ईकाई सीवर्ट या गैर-एसआई रेंटजेन समकक्ष मैन का उपयोग किया जाता है।


==विकिरण-संबंधी मात्राएँ==
==विकिरण-संबंधी मात्राएँ==
निम्न तालिका एसआई और गैर-एसआई इकाइयों में विकिरण मात्रा दर्शाती है:
निम्न सूची एसआई और गैर-एसआई इकाइयों में विकिरण मात्रा दर्शाती है:
{{Radiation related quantities}}
{{Radiation related quantities}}


Line 142: Line 132:
* रेड (इकाई) - अवशोषित अंश की सीजीएस इकाई
* रेड (इकाई) - अवशोषित अंश की सीजीएस इकाई
* रॉन्टगन समतुल्य मैन, या रेम - विकिरण अंश समतुल्य की इकाई
* रॉन्टगन समतुल्य मैन, या रेम - विकिरण अंश समतुल्य की इकाई
* सीवर्ट (प्रतीक: Sv) - अंश के बराबर की एसआई व्युत्पन्न इकाई
* सीवर्ट (प्रतीक: एसवी) - अंश के बराबर की एसआई व्युत्पन्न इकाई
* विल्हेम रॉन्टगन
* विल्हेम रॉन्टगन


Line 153: Line 143:
*[http://www.hps.org/publicinformation/ate/faqs/radiationdoses.html Radiation Dose Units] – Health Physics Society
*[http://www.hps.org/publicinformation/ate/faqs/radiationdoses.html Radiation Dose Units] – Health Physics Society


{{DEFAULTSORT:Roentgen}}[[Category: विकिरण खुराक की इकाइयाँ]] [[Category: गैर-एसआई मीट्रिक इकाइयाँ]]
{{DEFAULTSORT:Roentgen}}
 
 


[[Category: Machine Translated Page]]
[[Category:Created On 31/03/2023|Roentgen]]
[[Category:Created On 31/03/2023]]
[[Category:Lua-based templates|Roentgen]]
[[Category:Machine Translated Page|Roentgen]]
[[Category:Pages with script errors|Roentgen]]
[[Category:Templates Vigyan Ready|Roentgen]]
[[Category:Templates that add a tracking category|Roentgen]]
[[Category:Templates that generate short descriptions|Roentgen]]
[[Category:Templates using TemplateData|Roentgen]]
[[Category:Webarchive template wayback links]]
[[Category:गैर-एसआई मीट्रिक इकाइयाँ|Roentgen]]
[[Category:विकिरण खुराक की इकाइयाँ|Roentgen]]

Latest revision as of 16:07, 17 April 2023

रॉन्टगन
Dosimeter ablesung.jpg
Display of quartz fiber dosimeter, in units of roentgen.[1]
General information
इकाई प्रणालीलीगेसी यूनिट
की इकाईआयनीकरण विकिरण के संपर्क में
चिन्ह, प्रतीकR
नाम के बादविल्हेम रॉन्टगन
Conversions
1 R in ...... is equal to ...
   एसआई आधार इकाई   2.58×10−4 एस/किग्रा

रेंटजेन या रॉन्टगन (/ˈrɜːntɡən/; प्रतीक आर) मुख्यतः एक्स-रे और गामा किरणों के विकिरण से होने वाले खतरों के लिए मापन की मुख्य इकाई है, और इसे उस हवा के द्रव्यमान (स्टैट कूलम्ब प्रति किलोग्राम) से विभाजित हवा की निर्दिष्ट मात्रा में इस प्रकार के विकिरण द्वारा मुक्त विद्युत आवेश के रूप में परिभाषित किया गया है।

1928 में, इसे विकिरण सुरक्षा के लिए परिभाषित किए जाने वाले आयनीकरण विकिरण के लिए प्रथम अंतर्राष्ट्रीय माप मात्रा के रूप में अपनाया गया था, क्योंकि इस प्रकार तब यह आयन कक्ष का उपयोग करके वायु आयनीकरण को मापने की सबसे सरलता से दोहराई जाने वाली विधि थी।[2] इसका नाम जर्मनी के भौतिक विज्ञानी विल्हेम रॉन्टगन के नाम पर रखा गया है, जिन्होंने एक्स-रे की खोज की थी और इस खोज के लिए उन्हें भौतिकी का पहला नोबेल पुरस्कार दिया गया था।

चूंकि यह विकिरण मापन के मानकीकरण में बड़ी पहल थी, रेंटजेन का हानि यह है कि यह केवल वायु आयनीकरण का उपाय है, और इस प्रकार अन्य पदार्थों में विकिरण अवशोषण का प्रत्यक्ष उपाय नहीं है, जैसे कि मानव ऊतक के विभिन्न रूप में उदाहरण के लिए, रॉन्टजेन एकत्रीकरण में 0.00877 grays (0.877 rads) शुष्क हवा में अवशोषित अंश, या 0.0096 Gy (0.96 rad) कोमल ऊतक में इसका उपयोग किया गया हैं।[2] इसी प्रकार एक्स-रे का 0.01 to 0.04 Gy (1.0 to 4.0 rad) बीम ऊर्जा के आधार पर हड्डी में रॉन्टजेन का कहीं से भी एकत्रीकरण हो सकता है।[3] जैसा कि विकिरण मात्रामापी का विज्ञान विकसित हुआ, यह प्राप्त किया गया कि आयनीकरण प्रभाव, और इसलिए ऊतक क्षति, अवशोषित ऊर्जा से न कि केवल विकिरण खतरे से जुड़ी थी। इसके परिणामस्वरूप विकिरण सुरक्षा के लिए नई रेडियोमेट्रिक इकाइयां परिभाषित की गईं थी, जिन्होंने इसे ध्यान में रखा था। इस प्रकार 1953 में विकरण यूनिट्स एंड मेजरमेंट्स (आईसीआरयू) पर अंतर्राष्ट्रीय आयोग ने नई विकिरण मात्रा अवशोषित अंश के माप की इकाई के रूप में 100 ईआरजी/ग्राम के समान रेड की परिकाष्ठा की थी। इस प्रकार रेड को इकाइयों की सुसंगत सेंटीमीटर-ग्राम-दूसरी प्रणाली में व्यक्त किया गया था।[4]

1975 में ईकाई ग्रे (इकाई) को अवशोषित अंश की एसआई इकाई के रूप में नामित किया गया था। 1 ग्रे 1 जूल/किग्रा (अर्थात 100 रेड) के समान है। इसके अतिरिक्त नई मात्रा, केर्मा (भौतिकी), को वायु आयनीकरण के लिए उपकरण अंशांकन के लिए खतरे के रूप में परिभाषित किया गया था, और इससे अवशोषित अंश की गणना विशिष्ट लक्ष्यों के पदार्थों के लिए ज्ञात गुणांक का उपयोग करके की जाती है। आज विकिरण सुरक्षा के लिए, आधुनिक इकाइयां, ऊर्जा अवशोषण के लिए अवशोषित अंश और स्टोकेस्टिक प्रभाव के लिए समतुल्य अंश (सीवर्ट) का अत्यधिक उपयोग किया जाता है, और रेंटजेन का उपयोग संभवतः ही कभी किया जाता है। इस प्रकार बाट और माप की अंतर्राष्ट्रीय समिति (सीआईपीएम) ने कभी भी रॉन्टजेन के उपयोग को स्वीकार नहीं किया है।

रॉन्टजेन को वर्षों से पुनर्परिभाषित किया गया है। इसे आखिरी बार 1998 में यू.एस. के राष्ट्रीय मानक और प्रौद्योगिकी संस्थान (एनआईएसटी) द्वारा 2.58×10−4 C/kg रूप से परिभाषित किया गया था, इस अनुशंसा के साथ कि हर उस दस्तावेज़ में परिभाषा दी जाए जहाँ रेंटजेन का उपयोग किया जाता है।[5]

इतिहास

रेंटजेन मूल रूप से 1908 में अमेरिकन रॉन्टजेन रे सोसाइटी द्वारा परिभाषित विलार्ड इकाई में निहित किया गया हैं, जो विकिरण की मात्रा को प्रदर्शित करता है, यह इस प्रकार आयनीकरण द्वारा प्रति घन सेंटीमीटर विद्युत का स्टेटकूलम्ब मुक्त 3 सेमी तापमान और दबाव की सामान्य परिस्थितियों में वायु को प्रसारित करता है।[6][7] इस प्रकार 1 esu ≈ 3.33564×10−10 C का उपयोग करना और हवा का घनत्व ~1.293 किग्रा/मीटर3 तापमान 0°C और दबाव 101 किलो पास्कल पर निहित रहता हैं, यह 2.58 × 10−4 सी/किलोग्राम में परिवर्तित कर दिया जाता है, जो एनआईएसटी द्वारा दिया गया आधुनिक मान है।

1esu/cm3 × 3.33564 × 10−10C/esu × 1,000,000 cm3/m3 ÷ 1.293 kg/m3 = 2.58 × 10-4C/kg

अगले 20 वर्षों के लिए इस परिभाषा का उपयोग विभिन्न नामों (ई, आर, और विकिरण की जर्मन इकाई) के अनुसार किया गया था। इस बीच, फ्रांसीसी रोएंटजेन को अलग परिभाषा दी गई, जो 0.444 जर्मन आर की राशि थी।

आईसीआर परिभाषाएं

1928 में, रेडियोलॉजी की अंतर्राष्ट्रीय कांग्रेस (आईसीआर) ने एक्स-विकिरण की मात्रा के रूप में रॉन्टजेन को परिभाषित किया गया था, जो कि इस प्रकार द्वितीयक इलेक्ट्रॉनों का पूर्ण रूप से उपयोग किया जाता है और कक्ष की दीवार के प्रभाव से बचा जाता है, तो इस प्रकार 0 डिग्री पर वायुमंडलीय हवा के 1 सीसी में उत्पादन होता है। 1 सी और 76 सेमी पारा दबाव इस प्रकार की चालकता की डिग्री है कि 1 ईएसयू आवेश को संतृप्त धारा में मापा जाता है।[6] इस प्रकार बताए गए 1 सीसी हवा का द्रव्यमान 1.293 ग्राम होगा, इसलिए 1937 में आईसीआर ने आयतन, तापमान और दबाव के अतिरिक्त हवा के इस द्रव्यमान के संदर्भ में यह परिभाषा लिखी गई थी।[8] 1937 की परिभाषा को गामा किरणों तक भी बढ़ाया गया था, किन्तु बाद में 1950 में इसे 3 मेगा वोल्ट तक सीमित कर दिया गया था।

गोस्ट परिभाषा

सोवियत संघ मानकों की अखिल-संघ समिति (जीओएसटी) ने इस बीच 1934 में रेंटजेन की अधिक अलग परिभाषा को अपनाया था। जीओएसटी मानक 76230 डिग्री सेल्सियस पर हवा में विकिरणित आयतन का 3 और आयनीकरण पूर्ण होने पर सामान्य वायुमंडलीय दबाव ने इसे एक्स-रे की भौतिक अंश के रूप में परिभाषित किया है जो इस प्रकार प्रति सेमी परिमाण में विद्युत स्थैतिक इकाई के प्रत्येक आवेश का उत्पादन करता है।[9] इस अंश से भौतिक अंश के भेद ने भ्रम उत्पन्न किया गया था, जिनमें से कुछ ने कैंट्रिल और पार्कर की रिपोर्ट का नेतृत्व किया जा सकता है, इस प्रकार ऊतक के 83 ईआरजीएस प्रति ग्राम (0.0083 ग्रे (ईकाई)) के लिए रेंटजेन शॉर्टहैंड बन गया था।[10] आईसीआर राॅन्टजेन से अलग करने के लिए उन्होंने इस व्युत्पन्न मात्रा को राॅन्टजेन समकक्ष भौतिक (आरईपी) नाम दिया था।

आईसीआरपी परिभाषा

रॉन्टजेन मापन इकाई के प्रारंभ में हवा के आयनीकरण को मापने पर निर्भर थी, इसने पहले कम त्रुटिहीन प्रथाओं को परिवर्तित कर दिया जो समयबद्ध खतरे, फिल्म खतरे या प्रतिदीप्ति पर निर्भर करती थी।[11] इसने खतरे की सीमा को निर्धारित करने का मार्ग प्रशस्त किया, और इस प्रकार संयुक्त राज्य अमेरिका के विकिरण संरक्षण और माप पर राष्ट्रीय परिषद ने 1931 में प्रति दिन 0.1 रॉन्टजेन के रूप में पहली औपचारिक अंश सीमा स्थापित किया था।[12] इस प्रकार अंतर्राष्ट्रीय एक्स-रे और रेडियम संरक्षण समिति, जिसे अब रेडियोलॉजिकल प्रोटेक्शन (आईसीआरपी) पर अंतर्राष्ट्रीय आयोग के रूप में जाना जाता है, इसने शीघ्र ही 1934 में प्रति दिन 0.2 रेंटजेन की सीमा का पालन किया था।[13] इस प्रकार 1950 में, आईसीआरपी ने पूरे शरीर के खतरे के लिए उनकी अनुशंसित सीमा को घटाकर प्रति सप्ताह 0.3 रेंटजेन कर दिया था।

विकिरण इकाइयों और मापन पर अंतर्राष्ट्रीय आयोग (आईसीआरयू) ने 1950 में रेंटजेन की परिभाषा को अपने हाथ में ले लिया था, इसे X या γ-विकिरण की मात्रा के रूप में परिभाषित किया, जैसे कि हवा में प्रति 0.001293 ग्राम वायु से संबंधित कॉर्पसकुलर उत्सर्जन, हवा में, आयनों को ले जाता है। किसी भी संकेत की विद्युत की मात्रा की 1 विद्युत स्थैतिक इकाई के रूप में माना जाता हैं।[14] 3 मेव कैप अब परिभाषा का भाग नहीं था, किन्तु उच्च बीम ऊर्जा पर इस इकाई की निम्नीकृत उपयोगिता का उल्लेख साथ के पाठ में किया गया था। इस बीच रॉन्टजेन समतुल्य मानव (रेम) की नई अवधारणा विकसित की गई थी।

1957 से प्रारंभ होकर, आईसीआरपी ने रेम के संदर्भ में अपने प्रस्तावों को प्रकाशित करना प्रारंभ किया था, और रॉन्टजेन के लिए यह अनुपयोगी हो गया। चिकित्सा इमेजिंग समुदाय को अभी भी आयनीकरण माप की आवश्यकता है, किन्तु वे धीरे-धीरे 1 सी/किग्रा का उपयोग करने के लिए परिवर्तित हो गए क्योंकि विरासत उपकरण को परिवर्तित कर दिया गया था।[15] आईसीआरयू ने रेंटजेन को ठीक 2.58 × 10−4 सी/किलोग्राम 1971 में इसके रूप में पुनर्परिभाषित करने का प्रस्ताव रखा था।[16]

यूरोपीय संघ

1971 में यूरोपीय आर्थिक संघ, माप निर्देशों की यूरोपीय इकाइयों में इसका उपयोग किया था। इसके निर्देशानुसार 71/354/ईईसी, माप की उन इकाइयों को सूचीबद्ध करता है, जिनका उपयोग ... सार्वजनिक स्वास्थ्य ... उद्देश्यों के लिए किया जा सकता है।[17] इन निर्देशों में क्यूरी (इकाई) , रेड (ईकाई), वास्तविक (इकाई) और रेंटजेन को अनुमेय इकाइयों के रूप में सम्मिलित किया गया था, किन्तु यह आवश्यक था कि रेड, रेम और रेंटजेन के उपयोग की 31 दिसंबर 1977 से पहले समीक्षा की जाए। इस दस्तावेज़ ने रेंटजेन को परिभाषित किया था, जो बिल्कुल 2.58 × 10-4 सी/किलोग्राम, आईसीआरयू के परामर्श के अनुसार मापन निर्देशों की यूरोपीय इकाइयाँ इसके निर्देशों के अनुसार 80/181/ईईसी, दिसंबर 1979 में प्रकाशित किया गया था, इस प्रकार जिसने इस निर्देश 71/354/ईईसी को प्रतिस्थापित किया, इस उद्देश्य के लिए स्पष्ट रूप से ग्रे (ईकाई), बैक्यूएरेल और सीवर्ट को सूचीबद्ध किया था और आवश्यक किया कि क्यूरी, रेड, रेम और रॉन्टजेन को 31 दिसंबर 1985 तक समाप्त कर दिया जाएगा।[18]

एनआईएसटी परिभाषा

आज रॉन्टजेन का उपयोग संभवतः ही कभी किया जाता है, और इस प्रकार वज़न और माप के लिए अंतर्राष्ट्रीय समिति (सीआईपीएम) ने रॉन्टजेन के उपयोग को कभी स्वीकार नहीं किया था। 1977 से 1998 तक, यूएस एनआईएसटी के एसआई ब्रोशर के अनुवाद में कहा गया है कि सीआईपीएम ने अस्थायी रूप से 1969 से एसआई इकाइयों के साथ राॅन्टजेन (और अन्य रेडियोलॉजी इकाइयों) के उपयोग को स्वीकार कर लिया है।[19] चूंकि, परिशिष्ट में दिखाया गया एकमात्र संबंधित सीआईपीएम निर्णय 1964 में क्यूरी (ईकाई) के संबंध में है। इस प्रकार एनआईएसटी ब्रोशर ने रेंटजेन को 2.58 × 10−4 सी/किलोग्राम के रूप में परिभाषित किया है कि x या γ विकिरण के खतरे के साथ नियोजित किया जाना है, किन्तु आयनित होने के माध्यम को नहीं बताया था। इस प्रकार सीआईपीएम का वर्तमान एसआई ब्रोशर एसआई के साथ उपयोग के लिए स्वीकृत गैर-एसआई इकाइयों की सूची से रेंटजेन को बाहर करता है।[20] इस प्रकार यूएस एनआईएसटी ने 1998 में स्पष्ट किया कि वह एसआई प्रणाली की अपनी व्याख्या प्रदान कर रहा था, जिससे उसने एसआई के साथ अमेरिका में उपयोग के लिए रॉन्टजेन को स्वीकार किया था, जबकि यह स्वीकार किया कि सीआईपीएम ने नहीं किया।[21] तब तक, X और γ विकिरण की सीमा हटा दी गई थी। एनआईएसटी अनुशंसा करता है कि जहां इस इकाई का उपयोग किया जाता है वहां प्रत्येक दस्तावेज़ में रॉन्टजेन को परिभाषित किया जाता हैं।[5] एनआईएसटी द्वारा रॉन्टजेन के निरंतर उपयोग को दृढ़ता से हतोत्साहित किया जाता है।[22]

प्रतिस्थापन रेडियोमेट्रिक मात्राओं का विकास

रेडियोलॉजिकल सुरक्षा में उपयोग की जाने वाली बाहरी आधुनिक विकिरण मात्रा

चूंकि वायु आयन कक्ष के साथ मापने के लिए सुविधाजनक मात्रा, रेंटजेन का हानि था कि यह एक्स-रे की तीव्रता या उनके अवशोषण का प्रत्यक्ष माप नहीं था, बल्कि एक्स-रे के आयनिंग प्रभाव का माप था, इस प्रकार विशिष्ट परिस्थिति में 0 डिग्री सेल्सियस पर शुष्क हवा थी और दबाव का 1 मानक दबाव पर स्थिति किया गया था।[23]

इस कारण रेंटजेन का लक्ष्य पदार्थों में प्रति इकाई द्रव्यमान में अवशोषित ऊर्जा की मात्रा के लिए वैरियेबल से संयोजित था, क्योंकि विभिन्न पदार्थों में अलग-अलग अवशोषण विशेषताएँ होती हैं। जैसा कि विकिरण डोसिमेट्री का विज्ञान विकसित हुआ, इसे गंभीर कमी के रूप में देखा गया।

1940 में, लुई हेरोल्ड ग्रे, जो मानव ऊतक पर न्यूट्रॉन क्षति के प्रभाव का अध्ययन कर रहे थे, विलियम वेलेंटाइन मेनॉर्ड और रेडियोबायोलॉजिस्ट जॉन रीड के साथ मिलकर पेपर प्रकाशित किया था, जिसमें माप की इकाई ने ग्राम रेंटजेन (प्रतीक: जीआर) को डब किया था। न्यूट्रॉन विकिरण की उस मात्रा के रूप में परिभाषित किया गया है, जो विकिरण के रेंटजेन द्वारा पानी की इकाई मात्रा में उत्पादित ऊर्जा की वृद्धि के बराबर ऊतक की इकाई मात्रा में ऊर्जा में वृद्धि का उत्पादन करती है।[24] इस प्रकार यह प्रस्तावित किया गया था कि यह इकाई हवा में 88 ईआरजीएस के बराबर पाई गई थी। 1953 में आईसीआरयू ने अवशोषित विकिरण के माप की नई इकाई के रूप में 100 ईआरजी/ग्राम के बराबर रेड (ईकाई) की सिफारिश की। रेड को सुसंगत सीजीएस प्रणाली इकाइयों में व्यक्त किया गया था।[25]

1950 के दशक के उत्तरार्ध में भार और माप पर सामान्य सम्मेलन (सीजीपीएम) ने आईसीआरयू को अन्य वैज्ञानिक निकायों में सम्मिलित होने के लिए आमंत्रित किया जिससे कि वे इकाइयों की प्रणाली के विकास में भार और माप के लिए अंतर्राष्ट्रीय समिति (सीआईपीएम) के साथ कार्य कर सकें जो कि विभिन्न रूपों में निरंतर उपयोग किया जा सकता है। इस प्रकार यह निकाय प्रारंभ में इकाइयों की प्रणाली के लिए आयोग के रूप में जाना जाता था, जिसका नाम 1964 में इकाइयों के लिए सलाहकार समिति (सीसीयू) के रूप में परिवर्तित कर दिया गया था, इस प्रकार अंतर्राष्ट्रीय प्रणाली इकाइयों (एसआई) के विकास की देखरेख के लिए जिम्मेदार था।[26] उसी समय यह तेजी से स्पष्ट होता जा रहा था कि रेंटजेन की परिभाषा गलत थी, और 1962 में इसे फिर से परिभाषित किया गया था।[27]

सीसीयू ने अवशोषित विकिरण की एसआई इकाई को प्रति इकाई द्रव्यमान ऊर्जा के रूप में परिभाषित करने का निर्णय लिया, जो एमकेएस इकाइयों में जूल/किलोग्राम था। इसकी पुष्टि 1975 में 15वें सीजीपीएम द्वारा की गई थी, और इस प्रकार इस ईकाई का नाम लुई हेरोल्ड ग्रे के सम्मान में ग्रे रखा गया था, जिनकी मृत्यु 1965 में हुई थी। यह ग्रे 100 रेड के बराबर था। रॉन्टजन की परिभाषा में हवा में फोटॉनों को परिभाषित करने के लिए अपेक्षाकृत सरल होने का आकर्षण था, किन्तु ग्रे प्राथमिक आयनीकरण विकिरण प्रकार से स्वतंत्र है, और इसका उपयोग केर्मा और अवशोषित अंश दोनों के लिए व्यापक श्रेणी की स्थिति में किया जा सकता है।[28]

बाहरी खतरे के कारण मानव में अवशोषित अंश को मापते समय, एसआई इकाई ग्रे (ईकाई), या संबंधित गैर-एसआई रेड (ईकाई) का उपयोग किया जाता है। इनमें से अलग-अलग विकिरण प्रकारों और लक्ष्य पदार्थ से जैविक प्रभावों पर विचार करने के लिए अंश समकक्ष विकसित किए जा सकते हैं। ये समकक्ष अंश और प्रभावी अंश (विकिरण) हैं जिसके लिए एसआई ईकाई सीवर्ट या गैर-एसआई रेंटजेन समकक्ष मैन का उपयोग किया जाता है।

विकिरण-संबंधी मात्राएँ

निम्न सूची एसआई और गैर-एसआई इकाइयों में विकिरण मात्रा दर्शाती है:

Ionizing radiation related quantities view  talk  edit
Quantity Unit Symbol Derivation Year SI equivalent
Activity (A) becquerel Bq s−1 1974 SI unit
curie Ci 3.7 × 1010 s−1 1953 3.7×1010 Bq
rutherford Rd 106 s−1 1946 1,000,000 Bq
Exposure (X) coulomb per kilogram C/kg C⋅kg−1 of air 1974 SI unit
röntgen R esu / 0.001293 g of air 1928 2.58 × 10−4 C/kg
Absorbed dose (D) gray Gy J⋅kg−1 1974 SI unit
erg per gram erg/g erg⋅g−1 1950 1.0 × 10−4 Gy
rad rad 100 erg⋅g−1 1953 0.010 Gy
Equivalent dose (H) sievert Sv J⋅kg−1 × WR 1977 SI unit
röntgen equivalent man rem 100 erg⋅g−1 × WR 1971 0.010 Sv
Effective dose (E) sievert Sv J⋅kg−1 × WR × WT 1977 SI unit
röntgen equivalent man rem 100 erg⋅g−1 × WR × WT 1971 0.010 Sv

यह भी देखें

  • ग्रे (ईकाई) - अवशोषित अंश की एसआई इकाई
  • परिमाण के आदेश (विकिरण)
  • रेड (इकाई) - अवशोषित अंश की सीजीएस इकाई
  • रॉन्टगन समतुल्य मैन, या रेम - विकिरण अंश समतुल्य की इकाई
  • सीवर्ट (प्रतीक: एसवी) - अंश के बराबर की एसआई व्युत्पन्न इकाई
  • विल्हेम रॉन्टगन

संदर्भ

  1. Frame, Paul (2007-07-25). "Pocket Chambers and Pocket Dosimeters". Health physics historical instrument museum collection. Oak Ridge Associated Universities. Retrieved 2021-10-07.
  2. 2.0 2.1 "Princeton Radiation Safety Guide, Appendix E: Roentgens, RADs, REMs, and other Units". Archived from the original on 2015-02-22. Retrieved 10 May 2012.
  3. Sprawls, Perry. "विकिरण मात्रा और इकाइयां". The Physical Principles of Medical Imaging, 2nd Ed. Retrieved 10 May 2012.
  4. Guill, JH; Moteff, John (June 1960). "Dosimetry in Europe and the USSR". Third Pacific Area Meeting Papers — Materials in Nuclear Applications. Symposium on Radiation Effects and Dosimetry - Third Pacific Area Meeting American Society for Testing Materials, October 1959, San Francisco, 12–16 October 1959. American Society Technical Publication. Vol. 276. ASTM International. p. 64. LCCN 60014734. Retrieved 2012-05-15.
  5. 5.0 5.1 Hebner, Robert E. (1998-07-28). "Metric System of Measurement: Interpretation of the International System of Units for the United States" (PDF). Federal Register. US Office of the Federal Register. 63 (144): 40339. Retrieved 9 May 2012.
  6. 6.0 6.1 Van Loon, R.; and Van Tiggelen, R., Radiation Dosimetry in Medical Exposure: A Short Historical Overview Archived 2007-10-24 at the Wayback Machine, 2004>
  7. "Instruments de mesure à lecture directe pour les rayons x. Substitution de la méthode électrométrique aux autres méthodes de mesure en radiologie. Scleromètre et quantimètre". Archives d'électricité médicale. Bordeaux. 16: 692–699. 1908.
  8. Guill, JH; Moteff, John (June 1960). यूरोप और यूएसएसआर में डोसिमेट्री. Symposium on Radiation Effects and Dosimetry. Baltimore: ASTM International. p. 64. LCCN 60-14734. Retrieved 15 May 2012.
  9. Ardashnikov, S. N.; Chetverikov, N. S. (1957). "The definition of the roentgen in the "Recommendations of the International Commission on Radiological Units. 1953"". Atomic Energy. 3 (9): 1027–1032. doi:10.1007/BF01515739. S2CID 95827816.
  10. Cantrill MD, S.T.; Parker, H.M. (1945-01-05). सहिष्णुता की खुराक (Report). US Atomic Energy Commission, Argonne National Laboratory. Archived from the original on April 7, 2021. Retrieved 14 May 2012.
  11. Mutscheller, A. (1925). Physical standards of protection against Roentgen ray dangers, AJR. American Journal of Roentgenology, 13, 65–69.
  12. Meinhold, Charles B. (April 1996). One Hundred Years of X Rays and Radioactivity – Radiation Protection: Then and Now (PDF). International Congress. Vienna, Austria: International Radiation Protection Association. Retrieved 14 May 2012.
  13. Clarke, R.H.; J. Valentin (2009). "ICRP का इतिहास और इसकी नीतियों का विकास" (PDF). Annals of the ICRP. ICRP Publication 109. 39 (1): 75–110. doi:10.1016/j.icrp.2009.07.009. S2CID 71278114. Retrieved 12 May 2012.
  14. रेडियोलॉजिकल प्रोटेक्शन पर अंतर्राष्ट्रीय आयोग और रेडियोलॉजिकल यूनिट्स पर अंतर्राष्ट्रीय आयोग की सिफारिशें (PDF). National Bureau of Standards Handbook. Vol. 47. US Department of Commerce. 1950. Retrieved 14 November 2012.
  15. Carlton, Richard R.; Adler, Arlene McKenna (1 January 2012). "Radiation Protection Concepts and Equipment". Principles of Radiographic Imaging: An Art and a Science (5th ed.). Cengage Learning. p. 145. ISBN 978-1-4390-5872-5. Retrieved 12 May 2012.
  16. ICRU Report 19, 1971
  17. "Council Directive 71/354/EEC: On the approximation of the laws of the Member States relating to units of measurement". The Council of the European Communities. 18 October 1971. Retrieved 19 May 2012.
  18. The Council of the European Communities (1979-12-21). "Council Directive 80/181/EEC of 20 December 1979 on the approximation of the laws of the Member States relating to Unit of measurement and on the repeal of Directive 71/354/EEC". Retrieved 19 May 2012.
  19. International Bureau of Weights and Measures (1977). United States National Bureau of Standards (ed.). इकाइयों की अंतर्राष्ट्रीय प्रणाली (एसआई). NBS Special Publication 330. Dept. of Commerce, National Bureau of Standards. p. 12. Retrieved 18 May 2012.
  20. International Bureau of Weights and Measures (2006), The International System of Units (SI) (PDF) (8th ed.), ISBN 92-822-2213-6, archived (PDF) from the original on 2021-06-04, retrieved 2021-12-16
  21. Lyons, John W. (1990-12-20). "Metric System of Measurement: Interpretation of the International System of Units for the United States". Federal Register. US Office of the Federal Register. 55 (245): 52242–52245.
  22. Thompson, Ambler; Taylor, Barry N. (2008). इकाइयों की अंतर्राष्ट्रीय प्रणाली (एसआई) के उपयोग के लिए मार्गदर्शिका (2008 ed.). Gaithersburg, MD: National Institute of Standards and Technology. p. 10. SP811. Archived from the original on 16 May 2008. Retrieved 28 November 2012.
  23. Lovell, S (1979). "4: Dosimetric quantities and units". An introduction to Radiation Dosimetry. Cambridge University Press. pp. 52–64. ISBN 0-521-22436-5. Retrieved 2012-05-15.
  24. Gupta, S. V. (2009-11-19). "Louis Harold Gray". Units of Measurement: Past, Present and Future : International System of Units. Springer. p. 144. ISBN 978-3-642-00737-8. Retrieved 2012-05-14.
  25. Guill, JH; Moteff, John (June 1960). "Dosimetry in Europe and the USSR". Third Pacific Area Meeting Papers — Materials in Nuclear Applications. Symposium on Radiation Effects and Dosimetry - Third Pacific Area Meeting American Society for Testing Materials, October 1959, San Francisco, 12–16 October 1959. American Society Technical Publication. 276. ASTM International. p. 64. LCCN 60014734. Retrieved 2012-05-15.
  26. "CCU: Consultative Committee for Units". International Bureau of Weights and Measures (BIPM). Retrieved 2012-05-18.
  27. Anderson, Pauline C; Pendleton, Alice E (2000). "14 Dental Radiography". The Dental Assistant (7th ed.). Delmar. p. 554. ISBN 0-7668-1113-1.
  28. Lovell, S (1979). "3. The effects of ionizing radiation on matter in bulk". An introduction to Radiation Dosimetry. Cambridge University Press. pp. 43–51. ISBN 0-521-22436-5. Retrieved 2012-05-15.


बाहरी संबंध